APPENDIX D: Skew Compensation Module
Appendix D. Skew Module
The XR2000 receivers have an optional skew compensation module that
can be installed or removed.
To install the skew compensation module:
1 Remove top cover.
2 Remove the 3 jumpers from J16 pins 1-2, 4-5, 7-8.
4 Insert the Skew assembly onto the XR series PCB using 11 pin headers J16
and J17.
5 The correct orientation of the skew board is to place the side with the Magenta
logo into header J17.
6 Reassemble unit.
Removal is the opposite of the above. Ensure 3 jumpers are installed in
locations shown in Figure D-1.
Figure D-1.
Install 3 jumpers on J16 in
positions 1-2, 4-5, 7-8 as
shown if skew board is
removed.
Skew module placement on
headers J16/J17.